Central Heating Filters

TF1 Compact Filter

Designed for installation in small spaces or restricted access areas, this high performance in-line system filter uses hydrocyclonic and magnetic filtration to remove all types of contaminants from central heating system water.

TF1 Compact Filter
  • Removes system contaminants
  • Unique action, removes magnetic & non-magnetic contaminants
  • All valves and fittings included
  • Dosing point for Fernox ‘F’ range products
  • Will not block or restrict flow
  • Carbon Footprint certified by the Carbon Trust
  • Ideal for use in restricted spaces and access areas
  • Easy to fit - multiple orientation capability
  • Fast and easy to clean without dismantling unit
  • Fits horizontal and vertical pipework
  • As with all magnetic products, if you have an implanted cardiac device extra caution should be taken at all times when handling any Fernox TF1 filter

Product Specifications

  • Maximum temperature - 100°C
  • Maximum working pressure - 3 bar
  • Maximum flow rate - 50 L/min
  • Magnetic characteristics - 9000 Gauss Neodymium magnet assembly
  • Body material - Glass fibre reinforced nylon plastic

Dimensions and Weight

  • Height - 192 mm or 7.55”
  • Width - 157 mm or 6.18”
  • Depth - 109 mm or 4.29”
  • TF1 Compact with 22 mm valves - 1.4 kg
  • TF1 Compact 3/4” with valves - 1.34 kg

Product Uses

The Fernox TF1 Compact Filter (UK patent granted No. 2448232) is a high performance in-line filter, which allows hydrocyclonic action to deliver contaminants to the unit’s specially designed magnet assembly, removing and containing them from the system water.

The Fernox TF1 Compact Filter has been developed to fit into domestic heating systems where installation access may be restricted. In situations where headroom is limited, the TF1 Compact Filter can be installed at an angle of 45 degrees without compromising performance, to allow magnet removal when cleaning the unit.

Carbon Footprinting

Fernox has worked with the Carbon Trust to measure carbon emissions of the Fernox TF1 Range. Fernox has undergone rigorous carbon analysis to enable the TF1 Range to carry the Carbon Reduction Label.

Footprinting

Application

The Fernox TF1 Compact Filter can be connected directly onto pipework using the valve fittings provided. The unit can be installed in either horizontal or vertical pipework and has been conveniently designed to be positioned flush to a wall.

The TF1 Compact Filter can be installed in any one of 24 separate orientations enabled by its unique inlet/outlet mechanism, to allow the flow to be in any direction as it passes through the unit.

Packaging, Handling and Storage

Individually packaged with all valves and detailed instructions included. No special storage requirements needed.

Spare parts available from the Fernox Sales Office by
calling +44 (0) 330 100 7750

Product Codes

  • 22 mm - 62131
  • 3/4” - 62197

Pressure Loss

The following information shows the pressure loss in kPa over the TF1 Compact Filter under different flow rates. An average domestic central heating system flow rate of 15L/ m ( 0.25L/s) would result in a pressure drop over the TF1 Compact Filter of 2.0 kPa or 0.29 psi or 0.02 bar.

Average Flow Rate (l/m) Differential Pressure (kPa)
4.99 0.23
10.00 1.01
19.94 3.92
49.79 24.13
75.18 54.85
99.86 96.50
TF1 Compact Filter Graphic TF1 Compact Filter Graphic 2

TF1 Total Filter

A high performance in-line system filter, which uses hydrocyclonic and magnetic action to remove all types of contaminants from central heating system water

TF1 Total Filter
  • Unique action, removes magnetic & non-magnetic contaminants
  • Dosing point for Fernox ‘F’ range products
  • All valves and fittings included
  • Hydrocyclonic and magnetic in-line filter
  • Fits vertical and horizontal pipework
  • Cleaned in minutes without removal or disassembly
  • Will not block or restrict flow
  • Carbon Footprint certified by the Carbon Trust
  • As with all magnetic products, if you have an implanted cardiac device extra caution should be taken at all times when handling any Fernox TF1 filter

Product Specifications

  • Maximum temperature - 100°C
  • Maximum working pressure - 3 bar
  • Maximum flow rate - 50 L/min
  • Magnetic characteristics - 9000 Gauss Neodymium magnet assembly
  • Body material - Glass fibre reinforced nylon plastic

Product Codes

  • 22 mm - 59256
  • 28 mm - 59257
  • 3/4” - 59916
  • 1” - 59918

Dimensions and Weight

  • Height - 288 mm or 11.34”
  • Width - 157 mm or 6.18”
  • Depth - 109 mm or 4.29”
  • TF1 Total Filter with 22 mm valves - 1.53 kg
  • TF1 Total Filter with 28 mm valves - 1.76 kg
  • TF1 Total Filter 3/4” - 1.47 kg
  • TF1 Total Filter 1” - 1.69 kg

Product Uses

The Fernox TF1 Total Filter (UK patent granted No. 2448232) is a revolutionary in-line filter, which combines hydrocyclonic action with specially designed magnet assemblies, to remove both magnetic and non-magnetic contaminants from system water and contain safely within the filter.

Carbon Footprinting

Fernox has worked with the Carbon Trust to measure carbon emissions of the Fernox TF1 Range. Fernox has undergone rigorous carbon analysis to enable the TF1 Range to carry the Carbon Reduction Label.

Footprinting

Application

The Fernox TF1 Total Filter can be connected directly on to the pipework using the valve fittings provided. The Fernox TF1 Total Filter is supplied ready to install into vertical pipework with system water flowing upwards. Further installation instructions are provided with the unit.

The TF1 Total Filter can be installed in any one of 24 separate orientations enabled by its unique inlet/outlet mechanism, to allow the flow to be in any direction as it passes through the unit.

Packaging, Handling and Storage

Individually packaged with all valves and detailed instructions included.
No special storage requirements needed.

Spare parts are available from the Fernox Sales Office by calling +44 (0) 330 100 7750



Pressure Loss

The following information shows the pressure loss in kPa over the TF1 Total Filter under different flow rates. An average domestic central heating system flow rate of 15L/m (0.25L/s) would result in a pressure drop over the TF1 Total Filter of 1.0kPa or 0.145psi or 0.01 bar.

TF1 Total Filter Graphic TF1 Total Filter Graphic 2